HOME > Products > relay tester
4U3I economical protective relay test bench VAE-430
3-phase current(3×40A) + 4-phase voltage(4×120V) output

The VAE-430 protective relay tester is designed to test all the major protection testing projects, including the  27 underfrequency protection, 59 overcurrent protection, 67 undervoltage protection, 81 overfrequency protection, 87 differential protection, 51 time overcurrent protection, 50 boundary protection, 21 distance protection, 86 rate of change of frequency protection, and 32 directional power protection, and others. This tester is capable of accurately measuring and analyzing the performance of the tested power systems, ensuring that the relays operate within their specified parameters, and helping ensure the continuous and stable operation of the power grid.

+86 137 6011 6541 sales@va-tek.com
  • Descriptions
  • Specifications
  • Download
  • Video
Descriptions

Relay Test System

Universal Relay Test Set and Commissioning Tool

Powerful three-phase relay testing and more

Powerful current sources for testing even high-burden electromechanical relays. High current amplitudes for 5 A relay testing High accuracy and versatility for testing static and numerical relays of all types High accuracy injectional current for measure CT testing

Download Relay Test System Brochure

Key features

The VAE-430 is all-in-one relay tester, which outputs 3-phase current(3×40A) & 6-phase voltage(4×120V) for testing conventional protection relays. The new high-fidelity linear amplifier is used for VAE-430 to avoid high and medium frequency interference on the test site, and ensure smooth and accurate waveform from large current to small current.

supported test Applications:

  • AC/DC test
  • State Series
  • Harmonic Superposition Test
  • Power Direction & Impedance Test
  • Synchronization Test
  • Full Group Test I & II
  • Distance & Zero Sequence Protection
  • Differential test
  • Characteristic of Impedance
  • Differential Protection
  • Differential Harmonic

Compatible Apps

Universal AC Test

This application is mainly used to test the action value, return value, sensitivity angle, and action time of various AC relays such as voltage relays, current relays, and power direction relays. This application is also the most basic application of the entire testing system, which can provide 6 voltage and 6 current outputs simultaneously. In addition, under the manual control test mode, the amplitude, angle, and frequency of each voltage and current can be adjusted arbitrarily.

Distance & Zero Sequence Protection APP

In 110KV and above line protection, normally distance and zero sequence protection is set as main protection of line, and they often concentrate in a set of protective tester. The testing module of distance and zero sequence protection is a software developed aiming at this situation, which can complete automatically all kinds of earthing distance, phase to phase distance and zero sequence protection.

Differential Protection Test App

The unit of differential protection is designed according to the characteristics of micro-computer type or integrates circuit type transformer, generator and differential protection of Motor. It is used for testing automatically its characteristics of ratio control, harmonic control, action time, etc. Different from the ‘characteristic test of differential relay control’, this module does not do the test by directly loading action current and brake current on test, but loading primary current and secondary current on differential protective tester by simulating them,then it will combin action current and brake current by the protection.

 
Specifications

Current Generator

Setting range

3-phase AC(L-N)

3x0…40A

1-phase AC(LL-LN)

1x0…120A

DC(L-N)

3x…±10A

 

3-phase AC(L-N)

3x420VA at 40A

Power

1-phase AC(LL-LN)

1x900VA at 120A

 

DC(L-N)

3x120VA at 10A

Accuracy

AC: ≤0.2%

DC: ≤0.5%

 

Voltage Generator

Setting range

4-phase AC(L-N)

4x0…120V

1-phase AC(L-L)

1x0…240V

DC(L-N)

3x…±160V

Power

4-phase AC(L-N)

4x80VA at 120V

1-phase AC(L-L)

1x100VA at 240V

DC(L-N)

3x70VA at 160V

Accuracy

AC: ≤0.2%

DC: ≤0.5%

 

Auxiliary DC Supply

Voltage range

110V/220V(max.1.5A)

Power

max.165VA/330VA

 

Digital Inputs

Number

8

Input characteristics 

idle contact or potential-free contact

Threshold characteristics

“0”:0~6V; “1”:11V~250V

Max. measuring time 

0.1ms~9999s

Time accuracy   

0.1ms

 

Digital Outputs

Number

4

Type

idle contact

Break capacity

220VAC/0.5A, 220VDC/0.2A

 

General Generators

Frequency

range: 0~1000Hz(PC mode), 20~300Hz(local mode)

accuracy:<10mHz(0~450Hz),<20mHz(450~1000Hz)

resolution: 0.01Hz

Phase

range: 0~360°

accuracy: 0.2°

resolution: 0.1°

Harmonic

superposition orders: 1~20(PC mode), 1~6(local mode)

distortion: ≤0.5%

 

Power Supply

Nominal input voltage

customized(AC230V/120V±10%,1-phase)

Nominal frequency

50/60 Hz

Rated current

10A at 230V / 12A at 115V

Connection

standard AC socket (IEC 60320)

 

Environmental Conditions

Operation temperature

0 ... +50 °C (+32 ... +122 °F)

Storage temperature

-25 ... +70 °C (-13 ... +158 °F)

Humidity range

relative humidity 5 ... 95 %, non-condensing

Vibration

IEC 60068-2-6(20m/s2 at 10 ... 150 Hz)

 

Miscellaneous

Weight

19.7kg(43.43 lb)

Dimensions (W x H x D, without handle)

400×300×180mm(15.75x11.81x7.09 in)

Connection port

for PC connection

 

Copyright © 2020 VA TECHNOLOGY CO.,LTD All rights Reserved.

备案号:鄂ICP备2020021900号